per page

Grid  List 

Set Descending Direction

Items 1 to 20 of 21 total

Page:
  1. 1
  2. 2
  1. 110C/IS/250 Ventilation pipe

    110C/IS/250 Ventilation pipe

    Description: Insulated sewer ventilation pipe without a cowl. Installed on an on-site made sheet metal cone with opening Ø 170 mm.

    Dimensions: Duct Ø 110 mm, external Ø 160 mm, height 400 mm.

    Contents: Ventilation pipe, screws. Learn More
  2. 110P/200 Ventilation pipe + cowl

    110P/200 Ventilation pipe + cowl

    Description: Uninsulated ventilation pipe with a cowl. A pass-through according to the roofing material is required separately.

    Dimensions: Duct size Ø 110 mm, height above roof approx. 200 mm.

    Contents: Ventilation pipe, cowl, screws.

    This product will be replaced by a modern and energy efficient FLOW product. Learn More
  3. 110P/300 Ventilation pipe

    110P/300 Ventilation pipe

    Description: Uninsulated ventilation pipe without a cowl. A pass-through according to the roofing material is required separately. A VILPE® Cowl-110 is required for ventilation of attic space and roof structures.

    Dimensions: Duct size Ø 110 mm, height above roof approx. 300 mm.

    Contents: Ventilation pipe, screws. Learn More
  4. 110P/300 Ventilation pipe + cowl

    110P/300 Ventilation pipe + cowl

    Description: Uninsulated ventilation pipe with a cowl. A pass-through according to the roofing material is required separately.

    Dimensions: Duct size Ø 110 mm, height above roof approx. 300 mm.

    Contents: Ventilation pipe, screws, cowl.

    This product will be replaced by a modern and energy efficient FLOW product. Learn More
  5. 110P/IS/350 Ventilation pipe

    110P/IS/350 Ventilation pipe

    Description: Insulated sewer ventilation pipe. A pass-through according to the roofing material is required separately, and a VILPE® Flex pipe if needed. If used as a radon ventilator, a VILPE® Cowl 160 is needed.

    Dimensions: Duct size Ø 110 mm, height above roof approx. 350 mm.

    Contents: Ventilation pipe, screws. Learn More
  6. 110P/IS/350 Ventilation pipe + cowl

    110P/IS/350 Ventilation pipe + cowl

    Description: Insulated ventilation pipe with a cowl. A pass-through according to the roofing material is required separately.

    Dimensions: Duct size Ø 110 mm, height above roof approx. 300 mm.

    Contents: Ventilation pipe, screws, cowl.

    This product will be replaced by a modern and energy efficient FLOW product. Learn More
  7. 110P/IS/500 Ventilation pipe

    110P/IS/500 Ventilation pipe

    Description: Insulated sewer ventilation pipe. A pass-through according to the roofing material is required separately, and a VILPE® Flex pipe if needed. If used as a radon ventilator, a VILPE® Cowl 160 is needed.

    Dimensions: Duct size Ø 110 mm, external Ø 160 mm, height above roof approx. 500 mm.

    Contents: Ventilation pipe, screws. Learn More
  8. 125C/400 VENTILATION PIPE

    125C/400 VENTILATION PIPE

    Description: Underpressure air vent for ventilating the roof structures or attic space. Installed in a sheet metal cone with opening Ø 170 mm, made by a sheet metal worker.

    Dimensions: External Ø 160 mm, height 400 mm.

    Contents: Ventilation pipe, screws. Learn More
  9. 160P/500 Ventilation pipe

    160P/500 Ventilation pipe

    Description: Uninsulated ventilation pipe without a cowl. A pass-through according to the roofing material is required separately. VILPE® AP Cowl 160 is required for ventilation of attic space and roof structures.

    Dimensions: Duct size Ø 160 mm, height above roof approx. 500 mm.

    Contents: Ventilation pipe, screws. Learn More
  10. Freeze cover 110/475

    Freeze cover 110/475

    Description: Retrofittable. Insulation cover for old Ø 110 sewer ventilation pipes. Renewal of both appearance and colour.

    Dimensions: External Ø 160 mm, height 475 mm.

    Contents: Freeze cover, screws. Learn More
  11. KTV Classic ventilation set

    KTV Classic ventilation set

    Description: Roofing structure and roof space ventilation. Also suitable for drainage ventilation. Plain standing seam or if, retrofitted, also felt roofing. Thick rubber seal on the bottom of the flange. Sealing compound (not incl.) required on felt roofing.

    Contents: KTV ventilator, underlay ring, screws. Learn More
  12. KTV Decra ventilation set

    KTV Decra ventilation set

    Description: Roofing structure and roof space ventilation. Also suitable for drainage ventilation.

    Contents: Pass-through, underlay ring, sealing compound, screws. Learn More
  13. KTV Felt ventilation set

    KTV Felt ventilation set

    Description: Roofing structure and roof space ventilation. Also suitable for drainage ventilation. Plain standing seam or if, retrofitted, also felt roofing. Slate, shingle and felt roofing types.

    Contents: KTV ventilator, screws. Learn More
  14. KTV Felt ventilation set/Ridge

    KTV Felt ventilation set/Ridge

    Description: Underpressure air vent for ventilating the roof structures or attic space, for felt roofings. Installed on the ridge, on the pane or next to the wall.

    Contents: Ventilator Learn More
  15. KTV Profiled Steel ventilation set

    KTV Profiled Steel ventilation set

    Description: Ventilation of roof structures and roof space, drainage ventilation. For all round profiled metal sheet roofing types (tile-patterned). Minimum length of tile pattern 350 mm.

    Contents: KTV ventilation set, underlay ring, sealing compound, screws, installation instructions/template. Learn More
  16. KTV Steel ventilation set

    KTV Steel ventilation set

    Description: Roofing structure and roof space ventilation. Also suitable for drainage ventilation. Low profiled metal sheet roofing. Waterproof thanks to the rubber cone with the mouldable aluminium flange.

    Contents: KTV ventilator, underlay ring, sealing ring, sealing compound, screws. Learn More
  17. KTV Tile ventilation set

    KTV Tile ventilation set

    Description: Roofing structure and roof space ventilation. Also suitable for drainage ventilation. Replaces one concrete roof tile with tile width of 330 mm, and wave width and height 330 mm and 27-40 mm respectively.

    Contents: KTV ventilator, underlay ring, screws. Learn More
  18. KTV Tile ventilation set without adapter

    KTV Tile ventilation set without adapter

    Description: Roofing structure and roof space ventilation. Also suitable for drainage ventilation. Replaces one concrete roof tile with tile width of 330 mm, and wave width and height 330 mm and 27-40 mm respectively.

    Contents: KTV ventilator, underlay ring, screws. Learn More
  19. KTV Universal ventilation set

    KTV Universal ventilation set

    Description: Ventilation of roof structures and roof space, drainage ventilation. For all tile roofing types (ceramic, clay, concrete and special tiles, 1- and 2-wave tiles and plain tiles).

    Contents: KTV ventilation set, underlay ring, installation instructions, screws. Learn More
  20. Ridge capping vent

    Ridge capping vent

    Description: Underpressure air vent for ventilating the roof structures or attic space. For sheet metal roofing. Installed in round, angular or V-shaped ridge capping. Also retrofittable.

    Contents: Frame, seals, cover piece with a filter, screws, installation instructions. Learn More
per page

Grid  List 

Set Descending Direction

Items 1 to 20 of 21 total